Detailed information

The Novartos Uno triple sampler takes a triple target point sample from a predefined sampling area. For the triple sampler, a collection chamber is equipped with three sample inserts (accessories).

With the Novartos pharmaceutical sample collectors, several single-dose samples (unit-dose samples) can be taken from one or more sampling points in one sample train.

Thanks to the intelligent design of these pharmaceutical samplers, it is not necessary to pierce the sample several times for a multiple sample, thus largely avoiding segregation of the sample material. This is a particularly important requirement when taking very small quantities in the pharmaceutical industry.

With the Novartos sampler, a large number of samples can be taken quickly and easily, even from the same location, allowing representative retention samples to be taken.

The immersion depth of the sample lance is easy to read thanks to a laser-engraved depth scale. The rounded tip prevents the container from being scratched. Two additional handles ensure safe insertion, fixing and turning in the material. The precisely fitting inserts prevent mixing of the material and allow easy disassembly for thorough cleaning.

Thanks to the groove-free and electropolished surface of the pharmaceutical sample collectors and the high-quality workmanship, there are no gaps in which sample residues can settle, which is also a decisive advantage for easy cleaning.

Typical application area of the product

The Novartos Pharma Sampler is a highly specialized sampler that is mainly used in the pharmaceutical industry to meet the strict requirements of FDA guidelines for unit dose sampling. However, the application is not limited to the pharmaceutical sector, but can also be used in the chemical industry, the food and beverage industry, biotechnology, wherever the smallest quantities of powder need to be representatively sampled.

How to use the product
  1. With "1", move the sampler to the "CLOSE" position. The sampler is closed and can be inserted into the powder/granulate.
  2. Insert the sampler into the powder/granulate to the desired depth (the scale indicates the depth in cm).
  3. Move the sampler to the "OPEN" position at "1". The sampler is now open and is filled with sample.
  4. Move the sampler at "1" to the "CLOSE" position. The sampler is closed and the powder/granulate can be removed.
  5. If a second sample is to be taken, move the sampler to the "CLOSE" position at "2".
  6. Move the sampler at "2" to the "OPEN" position. The sampler is open and is filled with the second sample.
  7. Move the sampler at "2" to the "CLOSE" position. The sampler is closed and the powder/granulate can be removed.
  8. If a third sample is to be taken, move the sampler to the "CLOSE" position at "3".
  9. Move the sampler at "3" to the "OPEN" position. The sampler is open and is filled with the third sample.
  10. Move the sampler at "3" to the "CLOSE" position. The sampler is closed and the powder/granulate can be removed.
  11. Open the sampler and empty the sample onto an appropriately prepared surface or into a suitable collecting container.
  • Collecting lance Novartos Uno 3-fold sample train

Specifications

General material

1.4404 (316L)
Stainless steel 1.4404, AISI 316L

General material

1.4571
Stainless steel 1.4571, AISI 316Ti

Sample chamber details

Number of collection openings:
1 itms
Maximum coverage:
3 itms

Lance dimensions

Pipe Ø:
25 mm
Plunge depth:
600 mm
Total length:
800 mm

Collecting chamber dimensions

Chamber length:
45 mm
Start of the collecting chamber:
52.5 mm
Chamber width:
13 mm